View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0004382 | PicoCoreBBDSI_HW | Hardware | public | 2020-07-30 13:48 | 2021-02-19 06:52 |
| Reporter | baeder | Assigned To | |||
| Priority | normal | Severity | major | Reproducibility | always |
| Status | resolved | Resolution | fixed | ||
| Product Version | 1.20 | ||||
| Target Version | 1.30 | Fixed in Version | 1.30 | ||
| Summary | 0004382: RS485 does not work. | ||||
| Description | The connection of U14 is wrong. Processor RXD must be connected to pin 9. Processor CTS must be connected to pin 8. | ||||