View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0005858 | FSiMX6UL | FCR | public | 2023-07-06 09:39 | 2023-08-31 13:10 |
Reporter | froelich | Assigned To | |||
Priority | urgent | Severity | major | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | V1.60 | ||||
Target Version | V1.70 | Fixed in Version | V1.70 | ||
Summary | 0005858: Error after long run in case BINFS is larger than data partition (FAT/F3S) | ||||
Description | Error after long run in case BINFS is larger than data partition (FAT/F3S) | ||||
Additional Information | FCR thread starts from random page number, but always scans amount of pages of partition. If BINFS is larger than data part AND random page starts at end of BINFS, after long run page number could be larger than nand size and therfore begins at BCB/NBoot area. If fails there, because ECC level is different from rest of NAND. | ||||
Forum Link | |||||
Found Driver Version | 0.5 | ||||
Fixed Driver Version | 0.6 | ||||