Summary0005857: Error after long run in case BINFS is larger than data partition (FAT/F3S)
DescriptionError after long run in case BINFS is larger than data partition (FAT/F3S)
Additional InformationFCR thread starts from random page number, but always scans amount of pages of partition.
If BINFS is larger than data part AND random page starts at end of BINFS, after long run page number could be larger than nand size and therfore begins at BCB/NBoot area.
If fails there, because ECC level is different from rest of NAND.
Forum Link
Found Driver Version0.5
Fixed Driver Version0.6