View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0005480 | Eboot_iMX6UL | NAND-FMD | public | 2022-08-05 14:01 | 2022-08-05 14:04 |
Reporter | froelich | Assigned To | |||
Priority | normal | Severity | tweak | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | V2.00 | ||||
Target Version | V2.10 | Fixed in Version | V2.10 | ||
Summary | 0005480: Command XNS shows error when reading block 0 or block 1 (NBoot 0/1) | ||||
Description | Command XNS shows error when reading block 0 or block 1 (NBoot 0/1) | ||||
Steps To Reproduce | NBoot is stored with different data organization. There is no "SECINFO". Return dummy SECINFO when block 0 or block 1 is read by command XNS. | ||||
Forum Link | |||||
Found Driver Version | |||||
Fixed Driver Version | |||||