View Issue Details

IDProjectCategoryView StatusLast Update
0005401FSiMX6ULNAND-FMDpublic2022-09-08 10:27
Reporterfroelich Assigned To 
PrioritynormalSeverityfeatureReproducibilityN/A
Status resolvedResolutionfixed 
Product VersionV1.50 
Target VersionV1.60Fixed in VersionV1.60 
Summary0005401: Start page refresh when spare area has bit flips
DescriptionStart page refresh when spare area has bit flips
Additional InformationSpare has 3 copies of the same information. If two copies have bit flips, driver don't know which copy to use.
We should start refresh immediately after one bit is changed.
Forum Link
Found Driver Version1.3
Fixed Driver Version1.4

Relationships

has duplicate 0005402 resolvedfroelich FSiMX6SX Start page refresh when spare area has bit flips 

Activities