View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0004311 | FSiMX6SX | PowerManagement | public | 2020-05-29 06:20 | 2020-07-02 08:40 |
Reporter | zutter | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | V1.30 | ||||
Target Version | V1.40 | Fixed in Version | V1.40 | ||
Summary | 0004311: Add a "Dummy Power Management" for display (switch only PWM off/on) | ||||
Description | Exclusive for one customer that did connect VLCD, VBKL direct to VCC -> set only PWM by screen off/(on)to prevent flickering. Note, change contrast while "screenoff" is not possibel while using "dummy" at the time! | ||||
Steps To Reproduce | Many LCDs are flickering after screen off - screen on if VLCD and VBKL is not switched in the right order with Vsignal ... . | ||||
Forum Link | |||||
Found Driver Version | |||||
Fixed Driver Version | |||||