View Issue Details

IDProjectCategoryView StatusLast Update
0002881FSiMX6NAND-FMDpublic2018-04-05 16:04
ReporterAndermannAssigned To 
PrioritynormalSeverityminorReproducibilityhave not tried
Status resolvedResolutionfixed 
Product Versionv1.90 
Target VersionV2.50Fixed in VersionV2.50 
Summary0002881: Write failure will not be handled
DescriptionIn GPMI are checks missing in function "GpmiNandReadPageECC". In function "GpmiNandReadPage" are checks already included.
In the FMD the return value of the GPMI has to be handled!
Forum Link
Found Driver Version
Fixed Driver Version

Activities

There are no notes attached to this issue.